Razor Host

APIES (simultaneous Absorbance, Polarised Intrinsic Emission, and Scattering): a robust multi-attribute measurement system for biopharmaceuticals

Webinar

CPACT Webinar on

APIES (simultaneous Absorbance, Polarised Intrinsic Emission, and Scattering): a robust multi-attribute measurement system for biopharmaceuticals

Alan Ryder, University of Galway

26th November 2026 at 3pm (UK time)

Analysis of intrinsic fluorescence emission provides a label-free, non-destructive, and sensitive method for measuring quality attributes that is suitable as a biopharmaceutical Process Analytical Technology (PAT).  The full fluorescence emission space, captured using Excitation Emission Matrices (EEM), when coupled with multivariate data analysis provided a convenient analytical method for cell culture media [1] and bioprocesses [2].  Extending EEM with using UV transparent polarizers [3] enabled higher resolution polarised intrinsic emission (PIE) measurements of proteins which have been used for protein quality analysis [4], antibody-drug conjugate (ADC) reaction monitoring [5], and protein quantification [6]. 

A simpler and more robust derivative is APIES: simultaneous Absorbance, Polarized Intrinsic Emission, and Scattering measurements which is a rapid (<1 min.), robust measurement system.  APIES provides three orthogonal process data: protein concentration, degree of aggregation, and structural integrity.  This is easily implemented using a multichannel fluorometer fitted with UV transmitting polarizers and either standard quartz cuvettes (at-line) or quartz flows cells (online) [7].  We used APIES monitoring of low pH (3.4-3.8) Viral Inactivation (VIN) of IgG proteins under different pH conditions [7].  APIES both quantitatively tracked in-situ aggregation and also potentially discriminated between reversible and irreversible aggregates formed in-situ.  SEC did not observe the formation of the reversible aggregates in the reactor.  In a second case study, we used APIES for real-time monitoring of protein-liposome interactions [8] and here, using a simplified single excitation wavelength, we obtained a temporal resolution of 1 second.  This allowed the three phases of interaction (adsorption, penetration, and annealing) to be easily monitored.  Further work in my lab is ongoing to demonstrate the efficacy of APIES for ADC reaction and stability monitoring, downstream processing of mAbs, analysis of high concentration protein formulations, and cell culture media analysis. 

In conclusion, APIES is a fast, inexpensive, and efficient PAT ready measurement system for the downstream processing of biopharmaceuticals.

 

References:

1)    Li, B.; Ryan, PW.; Shanahan, M.; Leister, KJ.; Ryder, AG. Appl. Spectrosc. 2011, 65, 1240.

2)    Li, B.; Shanahan, M.; Calvet, A.; Leister, KJ.; Ryder, AG. Analyst 2014, 139, 1661.

3)    Casamayou-Boucau, Y.; Ryder, AG. Methods Appl Fluoresc 5, 037001, (2017).

4)    de Faria e Silva, A. L.; Elcoroaristizabal, S.; Ryder, AG. Anal. Chim. Acta 1101, 99-110, (2020).

5)    de Faria e Silva, AL.; Ryder, AG. Biotechnol. Bioeng. 119, 3432-3446,  (2022).

6)    Boateng, BO.; Ryder, AG. Anal. Chim. Acta 2026, 1383, 344894, (2026).

7)    Zang, JD.; Ryder, AG. Analytical Chemistry, 98, 26, 19533–19544, (2026).

8)    Wang, H.; Ryder, AG. Nanoscale 18, 11510 - 11524, (2026).

 

This webinar will take no longer than one hour.

 